7.4 Operator-level parameter list for EFKA controls DA82GA and 6F82FA-
The following pre-set values apply to class: 367
Parameter Name / Function Adj. range Pre-set
No. Abbr. Name / Function min max 100R
000 Arv starting-bar-tack stitches forwards
0 254 2
001 Arr starting-bar-tack stitches backwards
0 254 4
002 Err ending-bar-tack stitches backwards
0 254 3
003 Erv ending-bar-tack stitches forwards
0 254 3
004 LS number of light-barrier equalisation stitches
(large stitch length)
0 254 4
005 LSF number of light-barrier filter stitches for knits
0 254 0
006 LSn number of seams terminated with the light
barrier
0151
007 Stc number of stitches in the
automatically-produced seam section
0 254 10
008 F assigning a function to key 9
1 = So ftsta rt ON /O F F
2 = ornamental-stitch bar tack ON/OFF
3 = stroke adjustment
press and release = ON/ press and hold = OFF
4 = needle cooling ON/OFF
5 = handwheel reverse ON/OFF **
152
009 LS light barrier ON/OFF
OFF ON OFF
010 cLS number of light-barrier equalising stitches
(small stitch length)
0 254 8
013 FA thread cutter ON/OFF
OFF ON ON
014 FW thread retractor ON/OFF
OFF ON ON
015 StS stitch count ON/OFF
OFF ON ON
080 Sav number of stitches, starting decorative-stitch
bar tack forwards
0 254 3
081 SAr number of stitches, starting decorative-stitch
bar tack backwards
0 254 3
082 SEr number of stitches, ending decorative-stitch
bar tack backwards
0 254 3
083 SEv number of stitches, ending decorative-stitch
bar tack forwards
0 254 3
085** cFW residual-thread-monitor stitch count
F-195 = 1-3
F-195 = 4
0 2540 0
0 9990 0