7.2.4 Changing operator-level parameter values
The operator-level parameters are in the parameter list (see
section 7.4).
Turn on the main switch.
Press the P k ey. The first operator-level parameter F-000 is
displayed.
Press the +”or“- keys to move to the next or preceding
para me ter.
Press the E k ey. The value of the selected parameter is
displayed.
The parameter value can be changed with the + and -”keys.
Press the E k ey to save the change and display the next
para me ter,
or press the P key twice to save the change and leave
programming level.
CAUTION:
The changed parameter values are not saved unless a complete
seam is sew n after leaving programming level, i.e. the pedal is
pushed forw ards and then all the w ay back. If the drive is
sw itched off straight after leaving programming level, the changes
are lost.
7.2.5 Reducing the maximum rotation speed
The maximum speed can be reduced to adapt it to particular
applications.
The current maximum speed is shown in the display after each seam
has been completed. This value can now be directly changed with the
+ and - keys. The adjustment range lies between the values of
parameters F-111 (maximum value) and
F-121 (minimum value).
Caution:
Reducing the maximum rotation speed also reduces the rpm for
starting and ending bar tacks and f or counted seam sections
executed automatically.
7.2.6 Entering the technician-level code number:
(see set-up instructions)